Are you aware of the inspection requirements for your above-ground storage tanks?
Do you know how often they should be inspected or which tests are necessary to ensure compliance with industry standards?
If these questions leave you unsure, you’re not alone.
Understanding the above ground storage tank inspection requirements is essential for any business that relies on these tanks for storing hazardous or non-hazardous substances.
Regular inspections not only help you avoid costly accidents and fines but also ensure your operations remain efficient and compliant.
In this blog, we’ll break down the basics of above-ground storage tank inspection requirements, explain why they are so important, and show how outsourcing to NDT Group can save your business time and money while ensuring you meet all statutory regulations.
Why are above ground storage tank inspections important?
Above-ground storage tanks are subject to various risks over time, such as corrosion, cracking, and structural damage.
Left unchecked, these issues can lead to dangerous leaks, spills, or environmental contamination – posing a threat to public safety and your company’s reputation.
Compliance with industry standards and statutory regulations is not just a matter of good practice but a legal requirement.
Regular inspections ensure that your above ground storage tanks are operating safely and within legal boundaries, helping to avoid costly fines, environmental damage, and potential shutdowns.
Key inspection requirements for above ground storage tanks
- Visual inspections
Visual inspections are the first line of defence in monitoring the condition of above ground storage tanks. These checks focus on the exterior of the tank, looking for signs of corrosion, physical damage, and leaks. Frequent visual inspections are recommended to catch any immediate issues that could escalate into more significant problems.
- Non-Destructive Testing (NDT)
NDT methods are essential in assessing the internal condition of the tank without causing any damage. Techniques like ultrasonic thickness testing, magnetic particle testing, and radiography help identify hidden flaws like thinning walls, cracks, and corrosion. These methods are vital for meeting above ground storage tank inspection requirements and ensuring the long-term integrity of your assets.
- Leak testing
Leak testing is a mandatory part of above ground storage tank inspection protocols. This can be performed through various methods, such as hydrostatic testing, vacuum testing, or pressure testing. Leak testing helps prevent environmental contamination and ensures that your tank remains within operational safety limits.
- EEMUA 159 compliance
The EEMUA 159 standard outlines the specific inspection, repair, alteration, and reconstruction requirements for above-ground storage tanks. Compliance with EEMUA 159 ensures that your above ground storage tanks meet the necessary structural and safety standards. Inspections under this standard typically involve internal and external inspections, ultrasonic thickness readings, and evaluation of the tank’s foundation.
- Corrosion protection checks
Given that corrosion is one of the most common causes of above ground storage tank failure, inspecting the tank’s corrosion protection system is critical. This includes checking cathodic protection systems and coatings to ensure they are functioning correctly and extending the lifespan of the tank.
- Foundation and structural integrity
The foundation on which your above ground storage tank sits is just as important as the tank itself. Routine inspections should assess the condition of the foundation for any signs of settlement or erosion that could compromise the tank’s stability.
How often should inspections be conducted?
The frequency of inspections depends on several factors, including the type of material stored, the age and condition of the tank, and regulatory requirements.
According to EEMUA 159, external visual inspections should occur at least once a year, while more comprehensive internal inspections are typically required every 5 to 10 years, depending on the tank’s condition and service history.
Stay compliant and save money with NDT Group
Navigating the intricacies of above ground storage tank inspection requirements can be overwhelming, especially with evolving regulations and standards.
The good news? You don’t have to handle it all in-house.
By outsourcing your Asset Integrity Management (AIM) to a trusted provider like NDT Group, you can ensure that your tanks are inspected efficiently and in full compliance with all statutory requirements.
Outsourcing inspection services offers numerous benefits, including:
- Expertise: NDT Group has a team of highly trained professionals who specialise in the latest NDT techniques and compliance standards.
- Cost efficiency: Regular inspections can save you from the high costs of emergency repairs or environmental fines caused by leaks or spills.
- Reduced downtime: NDT Group’s efficient inspection processes minimise operational disruption, helping you maintain productivity.
- Up-to-date compliance: With NDT Group, you’ll never have to worry about missing inspection deadlines or falling out of compliance with regulatory changes.
Interested? Contact us today to discuss how we can help you with your above ground storage tank inspection requirements and other AIM needs.
Taking care of your above ground storage tank inspection requirements
Meeting above ground storage tank inspection requirements is essential for the safety, longevity, and regulatory compliance of your above ground storage tanks.
Regular inspections, utilising both visual checks and advanced NDT techniques, help you avoid costly problems and ensure the integrity of your storage assets.
By outsourcing your AIM needs to NDT Group, you can focus on your core operations while we take care of keeping your storage tanks safe, compliant, and efficient.
Save time, save money, and ensure peace of mind with our professional inspection services.
Be in the know, stay compliant, and protect your investment – reach out to NDT Group today!